PINNeAPPle Request a quote

Success stories · Case · antennas and RF

Before proposing a surrogate, we measured the solver

Six hundred and thirty configurations of a compact-range reflector solved twice, under the same conditions and metrics — to find out what each fidelity costs and where it errs.

Validated

Application
Compact-range reflector for antenna measurement (quiet zone)
Sector
Antennas, RF, measurement instrumentation
Topic
Two fidelities, learned correction, solve budget
Stack
2-D reflector model, physical optics (PO), integral-equation solve
Reference
Analytic conducting-cylinder series, reproduced to 0.6–0.9% error
768×estimated cost of the 3-D direct solve against physical optics: 4.3 h against 20 s per design
98%of the best design reached with 12 expensive solves, against 81% spending the same 12 blindly
0.6–0.9%direct-solve error against the exact series (physical optics is off by 500–780% on the same test)
630configurations solved twice, under the same conditions and metrics

Objective

Optimising a compact-range reflector — the part that sets the size of the quiet zone where the antenna is measured — takes hundreds of configurations. Physical optics is cheap and approximate; the exact solve is expensive. Without measuring both side by side, any surrogate or multi-fidelity proposal is a guess: you do not know what each side costs or where the cheap one errs.

Key results

  1. In 3-D the direct solve costs about 768× physical optics — 20 seconds against roughly 4.3 hours per design. The surrogate is not a preference, it is a necessity.
  2. Ranking by the cheap model already reaches 94% of the best design with 12 expensive solves; combining both fidelities reaches 97–98% on the same budget, against 81% for a blind search.
  3. Physical optics is only useful where you know how much it errs. Against the exact cylinder series it is off by 500–780%; the direct solve is off by 0.6–0.9%.

Two fidelities, the same metrics

All 630 configurations — reflector size, illumination and 18 edge profiles — were solved by both methods, with identical output metrics. The difference between them became a learned model, not a correction factor picked by hand.

The step before that is verifying each solver: the direct solve reproduces the analytic series of a conducting cylinder to 0.6–0.9% error. Without that anchor there would be no way to tell which of the two is right.

What the learned correction removes — and what it does not transfer

The correction reduces the physical-optics error per indicator inside the edge family tested. With a whole edge profile held out of training, 17–20% remains on the amplitude quantities and nothing remains on ripple, phase and useful width: the transfer has a limit, and the limit is measurable.

Left: how much of the physical-optics error the learned correction removes, per indicator — and what remains w
Left: how much of the physical-optics error the learned correction removes, per indicator — and what remains when an entire edge profile is held out of training. Right: fraction of the best design reached by the four strategies on the same budget of expensive solves.

What each side costs

The 3-D direct-solve cost was not measured directly: it comes from the measured cost of a single application of the dense integral operator, 391 seconds on the production mesh, repeated 40 times per solve. The rule that closes the account with the client's own solver is simple: for a direct solve of T seconds, divide T by 391 to get how many operator applications fit in the same time.

“No surrogate proposal should exist before measuring both sides on the same bench. The value was not in predicting better; it was in knowing how much each method errs and what it costs.”

Experiment record · compact-range reflector

Let's build your solution

Your engineering challenge could be our next project.

Talk to our team about Physics AI consulting or explore PINNeAPPle Studio for modeling and verification workflows.

Talk to an engineer